Minibooster HC25
HC25 for fast forward movement of cylinders: 11 different intensification factors
- PIN: 20 – 207 bar (inlet pressure)
- PH: 800 bar maximum (outlet pressure)
- PRETURN: As low as possible (return pressure to tank)
- POUTLET: PH = (PIN – PReturn) x I (intensification)
- Mounting: Inline tube
Part Number | Material Number | Intensification Factor | Dump Valve | Connection | Price | Add to Parts List |
---|---|---|---|---|---|---|
HC25 - 1.2 - A - 2 | 1.2 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 1.2 - A - 1 | 1.2 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 1.2 - B - 2 | 1.2 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 1.2 - B - 1 | 1.2 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 1.5 - A - 2 | 1.5 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 1.5 - A - 1 | 1.5 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 1.5 - B - 2 | 1.5 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 1.5 - B - 1 | 1.5 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 2.0 - B - 1 | 2.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 2.0 - A - 2 | 2.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 2.0 - A - 1 | 2.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 2.0 - B - 2 | 2.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 2.8 - B - 1 | 2.8 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 2.8 - A - 2 | 2.8 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 2.8 - A - 1 | 2.8 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 2.8 - B - 2 | 2.8 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 3.2 - B - 2 | 3.2 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 3.2 - B - 1 | 3.2 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 3.2 - A - 2 | 3.2 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 3.2 - A - 1 | 3.2 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 4.0 - A - 1 | 4.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 4.0 - B - 2 | 4.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 4.0 - B - 1 | 4.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 4.0 - A - 2 | 4.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 5.0 - A - 1 | 5.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 5.0 - B - 2 | 5.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 5.0 - B - 1 | 5.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 5.0 - A - 2 | 5.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 6.6 - A - 2 | 6.6 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 6.6 - A - 1 | 6.6 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 6.6 - B - 2 | 6.6 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 6.6 - B - 1 | 6.6 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 9.0 - A - 2 | 9.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 9.0 - A - 1 | 9.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 9.0 - B - 2 | 9.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 9.0 - B - 1 | 9.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 13.0 - A - 2 | 13.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 13.0 - A - 1 | 13.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 13.0 - B - 2 | 13.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 13.0 - B - 1 | 13.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 20.0 - B - 1 | 20.0 | B | 1 | £818.18 £981.82 Inc. VAT |
|
|
HC25 - 20.0 - A - 2 | 20.0 | A | 2 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 20.0 - A - 1 | 20.0 | A | 1 | £778.18 £933.82 Inc. VAT |
|
|
HC25 - 20.0 - B - 2 | 20.0 | B | 2 | £818.18 £981.82 Inc. VAT |
|
Minibooster HC25
- Accessories: Pilot-operated dump valve available
A Model = Without Dump Valves
B Model = With Dump Valves
Material certificate 3.1 on request
Description:
The HC25 is a compact unit weighing only 2.3 kg. It is ideal for use in a variety of applications where building and maintaining high pressure is required.
The HC25 incorporates a counterbalance valve, which allows fast-forward movement of a cylinder by directing the full inlet flow to pass directly through the booster section until the set pressure has been reached. Then the counterbalance valve opens, and the booster starts oscillating.
The HC25 booster will automatically stall when the high-pressure side H is reached. The booster will continuously compensate for oil consumption to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure.
An optional orifice can be mounted in the booster to reduce inlet flow to the maximum allowed for the intensification ratio selected.
General Functions:
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve (in the customer system) to the IN port, flowing freely through the internal check valves to the high-pressure side H.
When pump pressure is reached on the high-pressure side H, the internal check valves will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
Domestic and export sales enquiries are welcome from end users, original equipment machinery manufacturers and trade suppliers from all industrial sectors.
If you can’t find what you are looking for, need product pricing, delivery, technical support or associated services CONTACT HYQUIP or call our sales office +44 (0)1204 699959
Quantity | Unit discount | You Save |
---|