Cookies management by TermsFeed Generator
The HC4W miniBOOSTER

Minibooster HC4W

HC4W: 9 different intensification factors

  • PIN: Inlet pressure 20-207 bar
  • PH: 800 bar maximum (outlet pressure)
  • PRETURN: As low as possible (Return pressure to tank)
  • Intensification ratios: PH = (PIN - PReturn) i (Intensification)
  • Mounting: Inline tube

Products
Downloads
Description
Part Number Material Number Intensification Factor Dump Valve Connection Tested Price Add to Parts List
HC4W - 1.3 - G - 1 HC4W-1.3-G-1 1.3 G 1 Tested in Water On Enquiry
HC4W - 1.3 - B - 1 HC4W-1.3-B-1 1.3 B 1 Tested in Water On Enquiry
HC4W - 1.3 - A - 1 HC4W-1.3-A-1 1.3 A 1 Tested in Water On Enquiry
HC4W - 1.3 - G - 1S HC4W-1.3-G-1S 1.3 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.3 - B - 1S HC4W-1.3-B-1S 1.3 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.3 - A - 1S HC4W-1.3-A-1S 1.3 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.5 - G - 1S HC4W-1.5-G-1S 1.5 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.5 - B - 1S HC4W-1.5-B-1S 1.5 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.5 - A - 1S HC4W-1.5-A-1S 1.5 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.5 - B - 1 HC4W-1.5-B-1 1.5 B 1 Tested in Water On Enquiry
HC4W - 1.5 - A - 1 HC4W-1.5-A-1 1.5 A 1 Tested in Water On Enquiry
HC4W - 1.5 - G - 1 HC4W-1.5-G-1 1.5 G 1 Tested in Water On Enquiry
HC4W - 1.8 - G - 1 HC4W-1.8-G-1 1.8 G 1 Tested in Water On Enquiry
HC4W - 1.8 - B - 1 HC4W-1.8-B-1 1.8 B 1 Tested in Water On Enquiry
HC4W - 1.8 - A - 1 HC4W-1.8-A-1 1.8 A 1 Tested in Water On Enquiry
HC4W - 1.8 - A - 1S HC4W-1.8-A-1S 1.8 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.8 - G - 1S HC4W-1.8-G-1S 1.8 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 1.8 - B - 1S HC4W-1.8-B-1S 1.8 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.1 - G - 1S HC4W-2.1-G-1S 2.1 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.1 - B - 1S HC4W-2.1-B-1S 2.1 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.1 - A - 1S HC4W-2.1-A-1S 2.1 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.1 - G - 1 HC4W-2.1-G-1 2.1 G 1 Tested in Water On Enquiry
HC4W - 2.1 - B - 1 HC4W-2.1-B-1 2.1 B 1 Tested in Water On Enquiry
HC4W - 2.1 - A - 1 HC4W-2.1-A-1 2.1 A 1 Tested in Water On Enquiry
HC4W - 2.8 - G - 1 HC4W-2.8-G-1 2.8 G 1 Tested in Water On Enquiry
HC4W - 2.8 - B - 1 HC4W-2.8-B-1 2.8 B 1 Tested in Water On Enquiry
HC4W - 2.8 - A - 1 HC4W-2.8-A-1 2.8 A 1 Tested in Water On Enquiry
HC4W - 2.8 - G - 1S HC4W-2.8-G-1S 2.8 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.8 - B - 1S HC4W-2.8-B-1S 2.8 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 2.8 - A - 1S HC4W-2.8-A-1S 2.8 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 3.2 - G - 1S HC4W-3.2-G-1S 3.2 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 3.2 - B - 1S HC4W-3.2-B-1S 3.2 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 3.2 - A - 1S HC4W-3.2-A-1S 3.2 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 3.2 - G - 1 HC4W-3.2-G-1 3.2 G 1 Tested in Water On Enquiry
HC4W - 3.2 - B - 1 HC4W-3.2-B-1 3.2 B 1 Tested in Water On Enquiry
HC4W - 3.2 - A - 1 HC4W-3.2-A-1 3.2 A 1 Tested in Water On Enquiry
HC4W - 4.3 - A - 1 HC4W-4.3-A-1 4.3 A 1 Tested in Water On Enquiry
HC4W - 4.3 - G - 1 HC4W-4.3-G-1 4.3 G 1 Tested in Water On Enquiry
HC4W - 4.3 - B - 1 HC4W-4.3-B-1 4.3 B 1 Tested in Water On Enquiry
HC4W - 4.3 - G - 1S HC4W-4.3-G-1S 4.3 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 4.3 - B - 1S HC4W-4.3-B-1S 4.3 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 4.3 - A - 1S HC4W-4.3-A-1S 4.3 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 5.1 - A - 1S HC4W-5.1-A-1S 5.1 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 5.1 - G - 1S HC4W-5.1-G-1S 5.1 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 5.1 - B - 1S HC4W-5.1-B-1S 5.1 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 5.1 - G - 1 HC4W-5.1-G-1 5.1 G 1 Tested in Water On Enquiry
HC4W - 5.1 - B - 1 HC4W-5.1-B-1 5.1 B 1 Tested in Water On Enquiry
HC4W - 5.1 - A - 1 HC4W-5.1-A-1 5.1 A 1 Tested in Water On Enquiry
HC4W - 6.3 - G - 1 HC4W-6.3-G-1 6.3 G 1 Tested in Water On Enquiry
HC4W - 6.3 - B - 1 HC4W-6.3-B-1 6.3 B 1 Tested in Water On Enquiry
HC4W - 6.3 - A - 1 HC4W-6.3-A-1 6.3 A 1 Tested in Water On Enquiry
HC4W - 6.3 - G - 1S HC4W-6.3-G-1S 6.3 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 6.3 - B - 1S HC4W-6.3-B-1S 6.3 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 6.3 - A - 1S HC4W-6.3-A-1S 6.3 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 9.8 - G - 1S HC4W-9.8-G-1S 9.8 G 1S Tested in Hydraulic Oil On Enquiry
HC4W - 9.8 - B - 1S HC4W-9.8-B-1S 9.8 B 1S Tested in Hydraulic Oil On Enquiry
HC4W - 9.8 - A - 1S HC4W-9.8-A-1S 9.8 A 1S Tested in Hydraulic Oil On Enquiry
HC4W - 9.8 - G - 1 HC4W-9.8-G-1 9.8 G 1 Tested in Water On Enquiry
HC4W - 9.8 - B - 1 HC4W-9.8-B-1 9.8 B 1 Tested in Water On Enquiry
HC4W - 9.8 - A - 1 HC4W-9.8-A-1 9.8 A 1 Tested in Water On Enquiry

Minibooster HC4W

Accessories: Pilot operated dump valve available

A Model = Without Dump Valves

B Model =
With Dump Valves

G Model = Direct Proportionally Controlled

Description:

The HC4W is ideal for use in applications where a higher volume of high-pressure fluid is required. The HC4W is a compact stainless steel unit weighing only 4.5 kg, but it delivers up to 7.0 liters/min. outlet flow.

Like the HC2W, it raises supplied pressure and automatically compensates for consumption of media to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure relative to its flow capability.

General Functions:

The basic operation is illustrated in the function diagram. Water is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

HC4W Function Diagram


Domestic and export sales enquiries are welcome from end users, original equipment machinery manufacturers and trade suppliers from all industrial sectors.
If you can’t find what you are looking for, need product pricing, delivery, technical support or associated services CONTACT HYQUIP or call our sales office +44 (0)1204 699959

Quantity Unit discount You Save