Hydac Inline Pressure Filters DFNF /LFNF for Reversible Flow

HYDAC Inline Pressure Filters DFNF/LFNF ensure efficient filtration in hydraulic systems with flow rates up to 100 l/min and pressure levels up to 100 bar. Designed for reversible flow, they feature a screw-in filter bowl, clogging indicator connection, and optional bypass cracking pressure, providing reliable contaminant control and system protection.

Key Features:

  • Flow rates up to 100 l/min
  • Pressure levels up to 100 bar
  • Connections: G½ to G1

Description
Downloads

HYDAC Inline Pressure Filters DFNF /LFNF for Reversible Flow

  • Flow rates up to 100 l/min
  • Pressure levels up to 100 bar
  • Connections: G½ to G1
  • Installation sizes: 40, 63, 100

Feature:

  • The filter housings are designed in accordance with international regulations
  • They consist of a filter head and a screw-in filter bowl
  • DFNF and LFNF filters are suitable for flow in both directions
  • Without bypass valve
  • Bypass cracking pressure (optional) 7 bar (others on request)
  • Connection for a clogging indicator
  • Pressure setting of the clogging indicator 5 bar (others on request)
  • Special models and accessories available on request
  • Compatibility with hydraulic fluids ISO 2943
  • Certificates and approvals available on request

HYDAC filter elements are validated and their quality is constantly monitored according to the following standards:

  • ISO 2941, ISO 2942, ISO 2943, ISO 3724, ISO 3968, ISO 11170, ISO 16889

Filter elements are available with the following pressure stability values:

  • Betamicron® (BN4HC): 20 bar
  • Betamicron® (BH4HC): 160 bar
  • Wire mesh (W/HC): 20 bar